Cleaning Method 3
CLEANING METHODS |
Product Care Instructions Except:(See Cleaning Method 1) Plus: Note: The old style OSJG, Swan Jacob Gonioprism is not autoclavable. Use Cleaning Method 1. Cleaning Rinse: Immediately upon removal from patient’s eye, thoroughly rinse in cool or tepid water.Wash: Place a few drops of mild soap on a moistened cotton ball. Gently clean with a circular motion. Rinse: Thoroughly rinse in cool or tepid water, then dry carefully with a non-linting tissue. Then: Proceed with either disinfection or sterilization instructions. CAUTION If fluid/gas exchange has occurred, wipe lens with alcohol to remove any trace of oil present. If lens is not promptly and properly cleaned, permanent damage may result. Disinfection Soak In: GLUTARALDEHYDE 2% or 3.4% aqueous solution. Temperature per manufacturer instructions. Minimum exposure time: 20 minutes. Or: BLEACH 10% solution mixed at:1 part bleach to 9 parts water. Recommended exposure time: 10 minutes. CAUTION To avoid damage to the lens, do not exceed recommended exposure time. Then: Rinse lens thoroughly to remove disinfection solution. 3 cycles of 1 minute, with cool or tepid water is recommended. Dry carefully and place in a dry storage case. NOTE: These lenses are known to be compatible with: Asepti-Wipe, Cavi-cide, Cidex, Cidex OPA, DisCide Wipe, Enviro-cide, H2O2 – 3%, and Opti-Cide. CAUTION If used on an ulcerated cornea, lens must be sterilized before next procedure. Sterilization – EO Minimum Time: 1 hour Temperature: 130°F (54°C) Aeration Time: 12 hours Sterilization – Steam Autoclave Prep: Place product in sterilization case. Process: Gravity Cycle (wrapped) Temperature: 270°F (132°C) Time: 15 minutes minimum Dry Time: 15 minutes minimum Or Temperature: 250°F (121°C) Time: 30 minutes minimum Dry Time: 30 minutes minimum Pre-Vacuum Cycle (wrapped) Temperature: 270°F (132°C) Time: 4 minutes minimum Dry Time: 20 minutes minimum Or Temperature: 273°F (134°C) Time: 3 minutes minimum Dry Time: 20 minutes minimum CAUTION Use only distilled water in the steam sterilizer. If not distilled, mineral deposits from hard water (steam) will leave a cloudy film on the lens. The deposit can only be removed by regrinding and re-polishing the lens and repair costs approximate that of a new lens. Store: Biological peel pouch ensures sterility after the sterilization process. FOR IMMEDIATE USE ONLY - FLASH AUTOCLAVE Gravity Cycle (unwrapped) Temperature: 270°F (132°C) Time: 10 Minutes minimum Pre-Vacuum Cycle (unwrapped) Temperature: 270°F (132°C) Time: 4 minutes minimum Or Temperature: 273°F (134°C) Time: 3 minutes minimum Note: Allow Vitrectomy lenses to air cool. Rapid cooling as in a cool water rinse may fracture the lens. Sterilization – Sterrad 100S Follow manufacturer’s instructions. (Except: OPPWV, OPGVI, OPVI-3, OHBVE, OHFVE, OHMVE, OHWVE, OHSG-LH, OHSG-RH, OPFVI, OBVI, OLV-1-IN, OLV-1-IR, OFVI, OMVI, OCTK-6.5, OSJAG, OLV-OC, OLV-1S, OLV-5SR |